NRD-TM Series (6,000-30,000 CFM)
High Capacity Thermal Mass Refrigerated Dryers
The NRD-TM Thermal Mass High-capacity refrigerated air dryer combines the advantages of a direct thermal exchange with thermal storage. It’s two dryers in one. By combining these two powerful energy-saving technologies the NRD-TM provides you with the lowest power consumption available in the market today. This cutting-edge concept not only reduces your energy bill, it also offers steady dew point performance and reliable operation to ensure you have continuous, worry free, clean and dry compressed air.
With unique digital controls that automatically manage energy consumption and energy saving condensate drains that automatically adjust to demand – the NRD-TM cycling dryer saves energy and eliminates seasonal adjustments. It is the ultimate solution to remove moisture from your compressed air system.
Refrigerated dryers must be sized to handle the worst-case operating conditions they may encounter – the highest possible flow at the hottest possible inlet temperature on the highest day of the year. The power consumption needed to operate in these worst-case conditions is far greater than otherwise needed. Dryer demand is a function of both required air flow and ambient conditions. The NRD-TM takes advantage of this savings opportunity by significantly reducing power consumption to match actual demand.
NRD-TM Series Features
- Zero-purge drain system
- Pump pressure gauge
- Thermal storage temperature gauge
- Phase protection module
- High Temp module
- Pump failure indicator
- No-Flow indicator
- Pump starter with overload protection
- Compressor starter with overload protection
- Inlet Temperature Indicator
- Outlet temperature indicator
- Refrigerated discharge pressure
- Compressor sequencer (for units with multiple compressors)
- Pump Separator (for units with duplex pumps)
- Compressor on indicator
- Air inlet pressure gauge
- Air outlet pressure gauge
- Nema-12 Electrical Enclosure
Standard operating Voltage
- 460V / 3 PH / 60 HZ – Standard
- 575V / 3 PH / 60 HZ – Optional+
- 400-380V / 3 PH / 50 HZ – Optional+
COMPRESSOR TYPE
- NRD-TM-2500 To 5,000 (SCROLL)
- NRD-TM-6,000+ (SEMI-HEMTIC
HEAT EXCHANGER TYPE
- NRD-TM-2500 To 500 (STAINLESS STEEL -Plate)
- NRD-TM-10,000+ (SHELL & TUBE) ASME
Min/Max inlet air temperature
- 40 to 120 ° F
- 40 to 49 C
Design Pressure Range:
- 0 to 150 psig
- 0 to 14 bar
Design Ambient temperature
- 40 to 110° F
- 4 to 43° C
Condenser Cooling Options
- Water Cooled (Standard)
- Air Cooled (Optional+)
Refrigerant Type
- R404a
- R407C
Control Panel Enclosure
- NEMA 12
System Pressure Drop
- 5 to 4.5 Psig
- .2 to .3 Bar
Standard outlet pressure Dew Point
- -40° F / C
Controller
- 7” HMI Touch Screen Controller
NRD-TM Series Dryer Models
Correction Factors
Sizing
NRD-TM Series Options
- Duplex Pumping
- Multiplex Compressor
- Air-Cooled Condenser
- Remote condenser
- Compressor sequencer
- Three Valve By-Pass
- Mounted Pre & After Filtration
- Digital Dew Point Monitor
- Nema-4,12,7 electrical enclosure
Your next step toward working with NEXT Air & Gas is to contact us for a Quote. Fill out the information below and give us the appropriate information needed to get started. Be sure to fill out all the contact information and our team will reach out with any questions or concerns.
If you’d rather speak to Sales Engineering, feel free to contact us at (865) 635-8178.
Below are links to product information and brochures. Please click and download at your convenience. If you have any questions or suggestions on materials you think would be helpful, please call us at (865) 635-8178.
Principle of Operation
Hot saturated air from the aftercooler enters the air/air heat exchanger, where the air is pre-cooled by the cold, dry air leaving the heat exchanger. The pre-cooled air then enters the air/glycol heat exchanger, where it is cooled to its final dew point by chilled water/glycol, flowing in the counter-current through the shell. The chilled air passes through the moisture separator, which has a high efficiency of separation for different flow rates. Condensate is removed from the system without any loss of air via a zero purge drain valve. Finally, the cold, dryer air is reheated in the air/air heat exchanger by the incoming hot air for maximum volumetric efficiency before exiting the dryer. The water/glycol is chilled by a cycling refrigeration system and continuously pumped through the shell side of the air/glycol heat exchanger. The glycol flow rate remains constant, regardless of compressed air load. The refrigeration compressor unloads and / or cycles OFF when pre-set temperature is reached for water glycol, thus minimizing electrical power consumption.
- AIR INLET
- AIR OUTLET
- PRE-COOLER /RE-HEATER
- AIR TO AIR / GLYCOL HEAT EXCHANGER
- MOISTURE SEPARATOR
- EVAPORATOR
- COLD BANK STORAGE
- PUMP
- ISOLATION VALVES
- SOLENOID VALVE
- DEFROSTER
- COMPRESSOR
- SUCTION ACCUMULATOR
- CONDENSER
- FILTER DRYER
- SIGHT GLASS
17. THERMOSTATIC EXPANSION VALVE
NRD-TM Design Advantages
Next uses the most energy efficient components in the manufacture of these high-capacity Refrigerated Dryers. The dryers are custom-built to suit your design and application requirements
Compressors
Capacity and type of application determines the use of one of these three types of high-quality energy saving compressors.
Rotary Screw Compressor
Semi Hermetic Reciprocating Compressor
High Efficiency Scroll Compressor
Air Cooled Condenser
Air cooled condensers are constructed from high thermal efficiency copper tubes, coils and aluminum fins and are rated for 100 F ambient temperature.
NEMA Rated Electrical Enclosure
NEMA 12 enclosures are standard on all high capacity refrigerated dryers. Optional Controls , monitoring systems, indicators and NEMA 4, 4X, and NEMA 7 Enclosures are also available as an Option.
Separators
High efficiency centrifugal separators eliminate moisture from the air system. The unique design of the separator removes 99% of the water droplets with no mechanical movement and maintenance.
Water Cooled Condenser
Water cooled condensers are designed according to ASME standards with carbon steel shell and copper tubes to provide adequate cooling capacity that exceeds the refrigeration demand. They are equipped with head pressure control and energy saver water regulating valve.
Evaporators
Evaporators are either shell and tube type or brazed stainless steel plate type and are designed for high heat transfer efficiency. Each refrigeration zone has its own independent evaporator, so failure of one refrigeration compressor will have no effect on the other circuits.
Controller
State of the art PLCs (programmable Logic Controller) are used for close monitoring of the inlet, outlet and dew-point temperatures of these dryers, Their modular and versatile features make them suitable for various application including local and remote display.
Heat Exchangers
Next’s high thermal efficiency, ASME – stamped shell-tube type pre-cooler/ reheater and air to water/ glycol plate heat exchangers are designed for low pressure drop and maximum performance.
Demand-Activated, zero purge Condensate Drains
One of the important components of the dryer is the discharge of the condensate which has been removed from the compressed air supply. Next’s pneumatic zero purge drain system automatically discharges contaminated condensate from compressed air systems.